Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use

Product Details
Customization: Available
Certification: ISO9001, ECE, CE, ASME Storage Tank
Material: Carbon Steel ISO Storage Tank
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 8 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (18)
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
  • Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
Find Similar Products

Basic Info.

Model NO.
JSX404044IST
Type
Storage Tank
Loading Capacity
25000L for 40feet ISO Tank Container
Maximum Gross Weight
35000 Kg for 40feet ISO Tank Container
Tare
8600 Kg for 40feet ISO Tank Container
Design Temperature(ºC)
55 for 40feet ISO Tank Container
Operating Temperature(ºC)
-40~50 for 40feet ISO Tank Container
Filling Medium
1, 2-Tetrafluoroethane Via This Storage Tank
Tank Instruction
T75 for 40feet ISO Tank Container
Max. Payload (Kg)
22568 for 40feet ISO Tank Container
Hydro.Test Pressure(MPa)
2.18 for 40feet ISO Tank Container
Leakage Test Pressure(MPa)
1.38 for 40feet ISO Tank Container
Volume
11.8m * 2.13m * 2.18m
Length
40′
Gross Weight
30.4t
Experice
10 Years
Producing Period
>20 Days
Frame Size
>20FT
Life Span
<25 Years
Color
Customized
Transport Package
by Container Vessel for This Tanker Container
Specification
12460*2500*3980/mm carbon steel tanker
Trademark
JUSHIXIN
Origin
Mainland of China
HS Code
8609001200
Production Capacity
200units/Month for 40feet ISO Tank Container

Product Description

High Quality 40Feet 40440L T50/T75 LPG/LNG ISO Storage Tank

1. The functions of this series container tanker:
***This series tank semi trailers are suitable for the transportation 1,1,1,2-Tetrafluoroethane,LNG/LO2/LCO2/LIN/LOX/LAR/Liquid Ammonia/Liquid Argon,Etc. Gas.
*** The volume is under 50 cube meters, we can manufacture it according to your needs.


2.The related Specification for this container tanker:
Dimension of the 40FT 40.44CBM LNG Tank Container with BV&T75
Description and Specification of Commodity
Codes and regulations TSG R0005-2011 <Mobile Pressure Vessel Safety Technical Inspection Regulations>, "International Maritime Dangerous Goods Code" (IMDG CODE)
JB / T4780-2002 "Liquefied Natural Gas Tank Containers", Container Inspection Code-2012
Guidelines for tank container T75
Container Type 1AA
Rated weight 32723kgs
Maximum Allowed Loading Weight 14700kgs
Tare 18023kgs
Allowed stacking weight 192000kgs
Manufacturing license level Inside tank C3
outside tank
Max. Working Pressure(Mpa.) Inside tank(MPa) 0.7 
outside tank(MPa) -0.1(Vacuum)
Min. Working Tempretrues Inside tank -162 °C
outside tank -20°C
Design Pressure(Mpa.) Inside tank 0.8 
outside tank -0.1/0.2
Design Tempretrues Inside tank -196 °C
outside tank 50 °C
The Main material Cover inside tank S30408
outside tank Q345R
Shell inside tank S30408
outside tank Q345R
Overall Size(Frame)/L*W*H/mm 12192*2438*2591
Media Inside tank LNG
Media Characteristics Inside tank explosive
Paint Frame  30µm +40µm +50µm 
Shell 30µm +40µm +50µm 
Total Volume(L) 40440
Effective volume(L) 36400
Rated filling rate 90%
Corrosion allowance Inside tank 0mm
outside tank 1mm
Air tightness test pressure(Mpa) Inside tank 0.8mm
outside tank 0.2mm
Air pressure test pressure Inside tank(MPa) 0.92
Welding joint coefficient Inside tank 1
outside tank 0.85
Static evaporation rate Inside tank <=0.18
Material density(kg/m3) Inside tank 426
Natural boost rate Inside tank <=13
Main hazard category 2.1
Design service life 15 years
Mode of transportation Road,Sea or Railway
Adiabatic form High vacuum multilayer insulation
 Emergency cut-off valve Type Gas phase KDJ661F-16P
liquid phase KDJ661F-16P
Nominal pressure Gas phase(Mpa) 1.6
liquid phase(Mpa) 1.6
Nominal Diameter Gas phase DN50/DN32
liquid phase DN50
Operation way Gas phase Pneumatic motion control
liquid phase Pneumatic motion control
Fusible temperature for the Fusible alloy of the fusible plug(°C) 70+/-5
Safety valve Type ZA25-5B
Mode Low temperature modular safety valve
Level gauge Type ZK-1.5-6-1
Mould CYJ-1 Double liquid column pressure difference level gauge
Nominal pressure(Mpa) 1.6
Nominal Diameter DN6
Measuring range(Kpa) 0~15
Precision >=2.5
Loading and unloading device Gas phase joint Type Flange connection
Nominal Diameter DN50
liquid phase joint Type Flange connection
Nominal Diameter DN50
Pressure gauge Type YN-100
Measuring range(Mpa) 0~1.6
Precision 1.6 Class
Shell blasting device Burst pressure(Mpa) <=0.1
Nominal Diameter DN80
Type YEJ80-0.1-50
Orifice table
symbol Nominal  Size Nominal  Pressure Tube Size Purpose and Name Connection standard and Type
CZ1 50 40 Ø57*3.5 liquid phase entrance HG/T20592-2009
CZ2 50 40 Ø57*3.5 Gas phase entrance HG/T20592-2009
CZ3 32 40 Ø38*3 Supercharger liquid phase entrance HG/T20592-2009
j 80 / / Shell explosion-proof port /
Technical Requirements
1. This frame tank container should carry out all kinds of the test according to the GB / T16563-1996 and China Classification Society "Container Inspection Code".                                                    
2. Except for the pictures' mark, the type and size of the welded structure shall be in accordance with GB / 985.1. The height of the weld foot and weld fillet is according to the thickness of the less thinner steel plate.There should not be crack, slag, porosity, or undercut, etc. on the surface of the welded joint.Weld seam surface will be inspected through the magnetic powder or penetration testing (preferred magnetic powder). Meet NB / t47013.4 (5) -2015, Class I qualified.
3. The accessories shall meet the corresponding standards of product quality certification,which can be carried out the air tightness test together with the tank after passing the re-examination and form a complete set then delivery from the factory;
4 Valve opening operation,should be able to withstand the pressure of the air tightness test , fully open, fully closed, flexible operation, no abnormal resistance, idling and so on;
5 All signs, brand names, stickers will be made according to the drawings after the competion of the painting; The area around the signs, brand names and rivets will be sealed with the sealant.
6 The vertical plane of the longitudinal centerline of the tank shall be coincident with the vertical plane of the longitudinal centerline of the frame. The offset shall not exceed 5mm.
7 7. All supports of the connections between the tank and the frame should be thin welding, and welding firm and reliable, the weld seam surface shall not have cracks, undercut, stomatal, crater and splash.

 
8 8. Tank coating in line with the relevant provisions of JB / T4711-2003. After complete cleaning the rust of the outside carbon steel surface of the tank,coated two anti-rust primer, two white finish.
9 9. The tank needs to be replaced with nitrogen or vacuumed before leaving the factory.
(1) the use of nitrogen replacement treatment, the oxygen content after treatment is less than 3%, and keep the residual pressure 0.05Mpa ~ 0.1Mpar;
(2) the use of vacuum treatment, the vacuum after treatment is not less than 0.086Mpa.
10 10. Emergency cut-off device should be installed before the air tightness test, the test medium is air, the test pressure is 0.1Mpa;After the installation is complete, Emergency shut-off device should be done through emergency cut off and filter protection test, gas valve, liquid valve and booster valve completely closed in 5S qualified, air source control valve rotation flexibility, no jamming phenomenon.

3.Some photos for our ISO Storage Tank Container Workshop:
Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use
4.Detailed photos for the Gas Tank Container:
Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use


The Valves are all imported from the U.K.
Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use

5.Our customer testing the Air tightness for the gas tank container by themselves
Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use

Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use

6.FlEXIBLE SERVICE WE PROMISED FOR EACH ITEM FROM OUR FACTORY:
>>>Offering the one-stop full lifecycle services;
>>>Our vehicle users will receive 24-hour uninterruptible "Entire Journey" service;

>>>CCC&ISO Agreement, 1 Year Guarantee Term, Main-beam Lifetime Promise;
>>> Small Order Can Be Accepted;
>>>Any Color & Logo Available;
>>>The Product Dimension + Specifications Can Be Designed As Your Needs.


7.More styles for this ISO LNG Storage Tank Container
Premium 40FT 40440L LPG/LNG ISO Storage Tank for Global Use



8.Buying Guides for this ISO Storage Tank Container
**You please send us your enquiry;
**We shall reply you with the quotation within 12 hours;
**We negotiate on the configuration that you need;
**Confirmation of the tech data → sign contract (P/I) → 30% deposit (or L/C issuing)→ production;
**Manufacturing process updated news → completing production;
**Balance payment → ex works → shipment → custom clearance → A/S service for 1 year.

 
>>>Contact information
Maggie Suen
Office.:+86-371-55628659                    
Mobile:+86-13838278359
Website: hnjsx-trailer.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier